SerialLite II IP Core User Guide

ID 683179
Date 7/13/2021
Public
Document Table of Contents

2.8.14.1. Voltage Output Differential (VOD) Control Settings

The Stratix IV transceivers allow you to set the VOD to handle different length, backplane, and receiver requirements.

A range from 200 to 1,200 mV is supported for Stratix IV devices. Arria II GX devices have a fixed value, which cannot be changed. The range is decoded using the GUI integer value and the on-chip transmitter programmable termination values.

Table 13.  VOD Control SettingsThis table shows how the VOD value you chose in the SerialLite II parameter editor corresponds to the mV value. The VOD value is 0 by default.
VOD Value (Per Lane) 100 Ω (mV) Stratix IV
0 200
1 400
2 600
3 700
4 800
5 900
6 1,000
7 1,200