Due to a problem in the Intel® Quartus® Prime software versions 19.1, you may see the below error when selecting “Enable Multiple Dynamic Reconfiguration Profiles” and not selecting “Enable Dynamic Reconfiguration” in the Intel Stratix® 10 E-tile Transceiver Native PHY IP.
Error (19104): "S10_fit_error/altera_xcvr_native_s10_etile_191/synth/S10_fit_error_ip_parameters_wbuqy4a.tcl" cannot be found in the Quartus project database files. Please ensure the missing source file is listed as an SDC_ENTITY_FILE or TCL_ENTITY_FILE assignment in the Quartus Settings File (.qsf).
To work around this problem, you should select “Enable Dynamic Reconfiguration” and “Enable Multiple Dynamic Reconfiguration Profiles” in the Intel Stratix 10 E-tile Native PHY IP GUI.
This problem is scheduled to be fixed in a future version of the Intel Quartus Prime software.